All Aluminum Alloy Conductors (AAAC)

Minimum Order Quantity: 2KM;
Payment Type: T/T, L/C, MoneyGram, Credit Card, Western Union, Cash;
Shipping: Shipping fee and delivery date to be negotiated. Chat with supplier now for more details;
Secure Payments: Every payment you make is secured with strict SSL encryption and PCI DSS data protection protocols;
Delivery Terms: FOB, CFR, EXW, FAS, DDP;
Payment Currency: USD, EUR, CAD, AUD, GBP, CNY

Share:

Product Description

All Aluminum Alloy Conductors (AAAC)

Overhead Transmission AAAC Bare Conductors

All Aluminum Alloy Conductors Application

AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical features exist.

All Aluminum Alloy Conductors Construction

AAAC cable consists of aluminum alloy wires. The aluminum alloy wires are concentrically stranded.

This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant standard.

Conductors to all other recognized specifications can also be supplied. The alloys referred to have higher strength but lower conductivity than pure aluminium.

Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR; Having lower breaking loads than the later, their use becomes particularly favorable when ice and wind loadings are low.

All Aluminum Alloy Conductors Characteristics
Electrical Properties
  • Density at 20℃: 2.703 kg/dm3
  • Temperature Coefficient at 20°C: 0.00360 (°C)
  • Resistivity at 20°C: 0.03260Ω•mm2/m
  • Coefficient of linear expansion: 23 x10-6 (°C)
Service Conditions
  • Seismic Acceleration: 0.12 – 0.05g
  • Ambient Temperature: -5°C – 50°C
  • Wind Pressure: 80 – 130kg/m2
  • Isokeraunic Level: 10 – 18
  • Relative Humidity: 5 – 100%
All Aluminum Alloy Conductors Specifications
AAAC-All Aluminum Alloy Conductors IEC61089
Code Number            A2 Conductor                      A3 Conductor Max.D.C. Resistance of Conductor at 20°C
Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength Number of Wires Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
mm²

 

mm  mm kg/km   daN mm  mm kg/km   daN Ω/km
 16 7 1.83 5.49  50.4  5.43  50.8  6.04  50.8  6.04 1.7896
 25 7 2.29 6.87  78.7  8.49 1.1453  79.5  9.44  79.5  9.44 1.1453
 40 7 2.89 8.67 125.9  13.58 0.7158  127.1  15.1  127.1  15.1 0.7158
 63 7 3.63  10.8 198.3 21.39 0.4545 200.2 23.06 200.2 23.06 0.4545
100 19 2.78  13.9 316.3 33.95 0.2877 319.3 37.76 319.3 37.76 0.2877
125 19 3.10  15.5 395.4 42.44 0.2302 399.2 47.20 399.2 47.20 0.2302
160 19 3.51 17.55 506.1 54.32 0.1798 511.0 58.56 511.0 58.56 0.1798
200 19 3.93 19.65 623.7  67.91 0.1439 638.7 73.20 638.7 73.20 0.1439
250 19 4.39 21.95 790.8 84.68 0.1151 798.4 91.50 798.4 91.50 0.1151
315 37 3.53 24.71 998.9 106.95 0.0916 1008.4 115.29 1008.4 115.29 0.0916
400 37 3.98 27.86 1268.4 135.81 0.0721 1280.5 146.4o 1280.5 146.4o 0.0721
450 37 4.22 29.54 1426.9 152.79 0.0641 1440.5 164.70 1440.5 164.70 0.0641
500 37 4.45 31.15 1585.5 169.76 0.0577 1600.6 183.00 1600.6 183.00 0.0577
560 61 3.67 33.03 1778.4 190.14 0.0516 1795.3 204.95 1795.3 204.95 0.0516
630 61 3.89 35.01 2000.7 213.90 0.0458 2019.8 230.58 2019.8 230.58 0.0458
710 61 4.13 37.17 2254.8 241.07 0.0407 2276.2 259.86 2276.2 259.86 0.0407
800 61 4.38 39.42 2540.6 271.62 0.0361 2564.8 282.80 2564.8 282.80 0.0361
900 91 3.81 41.91 2861.1 305.58 0.0632 2888.3 329.40 2888.3 329.40 0.0321
1000 91 4.01 44.11 3179.0 339.53 0.0289 3209.3 366.00 3209.3 366.00 0.0289
1120 91 4.25 46.75 3560.5 380.27 0.0258 3594.4 409.92 3594.4 409.92 0 0258
All Aluminum Alloy Conductors IEC 61089 A3
IEC Spec
All Aluminum Alloy Conductors Type A3
Code
Name
Area
Actual
Equivalent
Copper Area
Stranding Overall
Diameter
Weight Rated
Strength
Maximum DC
Resistance
at 20℃
mm2 mm2 No/mm mm kg/km kN Ω /km
16 18.6 9.8 7/1.84 5.52 50.8 6.04 1.7896
25 29 15.2 7/2.30 6.9 79.5 9.44 1.1453
40 46.5 24.4 7/2.91 8.73 127.1 15.1 0.7158
63 73.2 38.4 7/3.65 10.95 200.2 23.06 0.4545
100 116 61 19/2.79 14 319.3 37.76 0.2877
125 145 76 19/3.12 15.6 399.2 47.2 0.2302
160 186 98 19/3.53 17.7 511 58.56 0.1798
200 232 122 19/3.95 19.8 638.7 73.2 0.1439
250 290 152 19/4.41 22.1 798.4 91.5 0.1151
315 366 192 37/3.55 24.9 1008.4 115.29 0.0916
400 465 244 37/4.00 28 1280.5 146.4 0.0721
450 523 275 37/4.24 29.7 1440.5 164.7 0.0641
500 581 305 37/4.47 31.3 1600.6 183 0.0577
560 651 342 61/3.69 33.2 1795.3 204.96 0.0516
630 732 384 61/3.91 35.2 2019.8 230.58 0.0458
710 825 433 61/4.15 37.4 2276.2 259.86 0.0407
800 930 488 61/4.40 39.6 2564.8 292.8 0.0361
900 1046 549 91/3.83 42.1 2888.3 329.4 0.0321
1000 1162 610 91/4.03 44.3 3209.3 366 0.0289
1120 1301 683 91/4.27 47 3594.5 409.92 0.0258
AAAC-All Aluminum Alloy Conductors BS EN 50183
Code Stranding Nominal Area Sectional Area Overall Diameter Weight Rated Strength Electrical Resistance Current Rating*
No.×mm mm^2 mm^2 mm kg/km KN Ω/Km A
Box 7/1.85 15 18.8 5.55 51.4 5.55 1.748 87
Acacia 7/2.08 20 23.8 6.24 64.9 7.02 1.3828 101
Almond 7/2.34 25 30.1 7.02 82.2 8.88 1.0926 116
Cedar 7/2.54 30 35.5 7.62 96.8 10.46 0.9273 129
Deodar 7/2.77 35 42.2 8.31 115.2 12.44 0.7797 143
Fir 7/2.95 40 47.8 8.85 130.6 14.11 0.6875 155
Hazel 7/3.30 50 59.9 9.9 163.4 17.66 0.5494 178
Pine 7/3.61 60 71.6 10.83 195.6 21.14 0.4591 199
Holly 7/3.91 70 84.1 11.73 229.5 24.79 0.3913 219
Willow 7/4.04 75 89.7 12.12 245 26.47 0.3665 228
7/4.19 80 96.52 12.57 264 27.17 0.3411 245
7/4.44 90 108.0 13.32 298 30.65 0.3023 260
Oak 7/4.65 80 118.9 13.95 324.5 35.07 0.2767 272
19/2.82 100 118.70 14.1 326 33.42 0.2787 290
Mulberry 19/3.18 125 150.9 15.9 414.3 44.52 0.2192 314
Ash 19/3.48 150 180.7 17.4 496.1 53.31 0.183 351
Elm 19/3.76 175 211 18.8 579.2 62.24 0.1568 386
Poplar 37/2.87 200 239.4 20.09 659.4 70.61 0.1387 416
37/3.05 225 270.30 21.35 744 76.08 0.1227 448
Sycamore 37/3.23 250 303.2 22.61 835.2 89.4 0.1095 480
Upas 37/3.53 300 362.1 24.71 997.5 106.82 0.0917 535
Walnut 37/3.81 350 421.80 26.67 1162 118.72 0.07860 584
Yew 37/4.06 400 479 28.42 1319.6 141.31 0.0693 633
Totara 37/4.14 425 498.1 28.98 1372.1 146.93 0.0666 648
Rubus 61/3.50 500 586.9 31.5 1622 173.13 0.0567 714
Sorbus 61/3.71 600 659.4 33.39 1822.5 194.53 0.0505 764
Araucaria 61/4.14 700 821.1 37.26 2269.4 242.24 0.0406 868
Redwood 61/4.56 800 996.2 41.04 2753.2 293.88 0.0334 970
AAAC-All Aluminum Alloy Conductors NFC 34 125
name name actual section no. of wire wire diameter conducto diameter conductor weight appr. calc. breaking force calc.conductor resistance
NF-C 34125 EN 50182 mm² mm mm kg/km kN Ohm/km
ASTER 22 22-AL4 22,0 7 2,00 6,00 60,0 7,15 1,498
ASTER 34,4 34-AL4 34,4 7 2,50 7,50 93,5 11,17 0,959
ASTER 54,6 55-AL4 54,6 7 3,15 9,45 148,9 17,73 0,604
ASTER 75,5 76-AL4 75,5 19 2,25 11,3 207,4 24,55 0,438
ASTER 117 117-AL4 117,0 19 2,80 14,0 321,2 38,02 0,283
ASTER 148 148-AL4 148,1 19 3,15 15,8 406,6 48,12 0,223
ASTER 181,6 182-AL4 181,6 37 2,50 17,5 500,3 59,03 0,183
ASTER 228 228-AL4 227,8 37 2,80 19,6 627,6 74,04 0,146
ASTER 288 288-AL4 288,3 37 3,15 22,1 794,3 93,71 0,115
ASTER 366 366-AL4 366,2 37 3,55 24,9 1.008,9 115,36 0,090
ASTER 570 570-AL4 570,2 61 3,45 31,1 1.576,0 185,33 0,058
ASTER 851 851-AL4 850,7 91 3,45 38,0 2.360,7 276,47 0,039
ASTER 1144 1144-AL4 1.143,5 91 4,00 44,0 3.173,4 360,22 0,029
ASTER 1600 1600-AL4 1.595,9 127 4,00 52,0 4.427,5 502,72 0,021
AAAC-All Aluminum Alloy Conductors ASTM B 399
Conductor size No./Diameter of single wire Approximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
kN
Maximum DC
Resistance at 20℃
Ω/km
AWG or MCM mm2
6 13.3 7/1.55 4.67 36.89 4.22 2.5199
4 21.14 7/1.96 5.89 57.89 6.71 1.586
2 33.65 7/2.47 7.42 92.14 10.69 0.9987
1/0 53.49 7/3.12 9.35 146.5 16.98 0.6259
2/0 67.45 7/3.50 10.52 184.7 20.48 0.4974
3/0 85 7/3.93 11.79 232.7 25.88 0.3945
4/0 107.2 7/4.42 13.26 293.7 32.67 0.3119
250 126.7 19/2.91 14.58 346.9 38.97 0.2651
300 152.1 19/3.19 15.89 418.6 46.77 0.2206
350 177.3 19/3.46 17.25 485.5 52.26 0.1886
400 202.7 19/3.69 18.44 555.1 59.76 0.1649
450 228 19/3.91 19.56 624.4 67.25 0.1468
500 253.4 19/4.12 20.6 693.6 74.65 0.1322
550 278.7 37/3.10 21.67 762.9 83.84 0.12
600 304 37/3.23 22.63 832 91.43 0.1105
650 329.4 37/3.37 23.57 909.8 99.03 0.1015
700 354.5 37/3.49 24.46 910.6 101.93 0.09464
750 380.2 37/3.62 25.32 1041 109.92 0.08796
800 405.4 37/3.73 26.14 1109 116.91 0.08285
900 456.3 37/3.96 27.74 1249 131.91 0.07351
1000 506.7 37/4.18 29.24 1388 145.89 0.06597
1250 633.3 61/3.63 32.67 1733 179.87 0.05306
1500 760 61/3.98 35.82 2081 216.84 0.04414
1750 886.7 61/4.30 38.7 2429 252.82 0.03781
All Aluminium Alloy Conductors(AAAC) to ASTM B 399 Standard
Code Conductor size No./Diameter of single wire Approximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
kN
Maximum DC
Resistance at 20℃
Ω/km
AWG or MCM mm2
Akron 30.58 15.48 7/1.68 5.04 42.68 4.92 2.1556
Alton 48.69(4) 24.67 7/2.12 6.35 67.56 7.83 1.3557
Amas 77.47(2) 39.26 7/2.67 8.02 107.5 12.5 0.8547
Azusa 123.3(1/0) 62.46 7/3.37 10.11 171 19.79 0.5365
Anahelm 155.4(2/0) 78.75 7/3.78 11.35 215.16 23.98 0.4264
Amherst 195.7(3/0) 99.2 7/4.25 12.75 271.5 30.17 0.3373
Altiance 246.9(4/0) 125.1 7/4.77 14.3 342.6 38.07 0.2678
Butte 312.8 158.5 19/3.26 16.31 434 48.76 0.2112
Canton 394.5 199 19/3.66 18.31 547.4 58.96 0.1676
Calro 465.4 235.8 19/3.98 19.89 645.7 69.55 0.1431
Darien 559.5 283.5 19/4.36 21.79 776.3 83.55 0.1181
Elgin 652.4 330.6 19/4.71 23.55 970.6 97.43 0.1012
Flint 740.8 375.4 37/3.59 25.15 1028 107.93 0.08944
Greeley 927.2 469.8 37/4.02 28.14 1287 135.91 0.07133
AAAC-All Aluminum Alloy Conductors DIN 48201
Aluminium Alloy Conductors (AAAC) DIN 48201
Code Number Area. No.of wires Diameter Linear Mass Rated Tensile strengrh DC Resistance
at 20℃
Wire Cond.
mm 2 mm 2 mm mm kg/km daN Ω/km
16 15.89 7 1.7 5.1 43.3 444 2.091
25 24.25 7 2.1 6.3 66.2 677 1.3703
35 34.36 7 2.5 7.5 93.8 960 0.9669
50 49.48 7 3 9 135.1 1382 0.6714
50 48.35 19 1.8 9 132.7 1350 0.6905
70 65.81 19 2.1 10.5 180.7 1838 0.5073
95 93.27 19 2.5 12.5 256 2605 0.3579
120 116.99 19 2.8 14 322 3268 0.2854
150 147.11 37 2.25 15.8 406 4109 0.2274
185 181.62 37 2.5 17.5 500.3 5073 0.1842
240 242.54 61 2.25 20.3 670.3 6774 0.1383
300 299.43 61 2.5 22.5 827 8363 0.112
400 400.14 61 2.89 26 1104 11176 0.0838
500 499.63 61 3.23 29.1 1379 13960 0.06709
625 626.2 91 2.96 32.6 1732 17490 0.054
800 802.09 91 3.35 36.9 2218 22402 0.0418
1000 999.71 91 3.74 41.1 2767 27922 0.0335
AAAC-All Aluminum Alloy Conductors AS 1531
AAAC 6201- All Aluminium Alloy Conductor AS 1531
Code Name Strands/Wire Diameter Overall Diameter (Approx) Calculated Equivalent Aluminium Area Sectional Area Approx.
Mass
Calculated Minimum Breaking Load D.C.Resistence
at 20℃
mm mm mm2 mm2 kg/km kN Ω/km
Agate 7/1.75 5.25 14.3 16.84 46 4.71 1.972
Amethyst 7/2.25 6.75 23.7 27.83 76 7.78 1.194
Diamond 7/2.50 7.50 29.3 34.36 94 9.64 0.967
Dolomite 7/2.75 8.25 35.4 41.58 114 11.6 0.799
Emerald 7/3.00 9.00 42.2 49.48 136 13.9 0.671
Garnet 7/3.75 11.3 65.8 77.28 211 21.7 0.43
Jade 7/4.50 13.5 94.8 111.3 304 31.2 0.298
Jasper 7/4.75 14.3 106 124.0 340 34.8 0.268
Opal 19/3.25 16.3 134 157.6 433 44.2 0.212
Patronite 19/3.50 17.5 155 182.80 502 51.3 0.183
Pearl 19/3.75 18.8 178 209.8 577 58.8 0.159
Ruby 37/3.00 21.0 221 261.60 720 73.5 0.128
Ruthenium 37/3.25 22.8 260 307.00 845 86.1 0.109
Rutile 19/4.75 23.8 285 336.7 925 94.4 0.09991
Sapphire 37/3.75 26.3 345 408.50 1125 115 0.0819
Spinel 61/3.25 29.3 427 506.10 1396 135 0.0662
Tantalum 61/3.50 31.5 495 586.90 1620 156 0.0572
Topaz 61/3.75 33.8 568 673.40 1858 179 0.0498
Zircon 91/4.50 49.5 1220 1447 3997 384 0.0232
AAAC-All Aluminum Alloy Conductors IS 398 PART 4
Name ref. Conductor cross-section
(mm2)
Stranding
(No./mm)
Nominal overall diameter
(mm)
Approximate weight
(kg/km)
Current Carrying Capacity at 45ºC
(Amp)
Mole 15 3/2.50 5.38 40.15 65
Squirrel 22 7/2.00 6.00 60.16 105
Weasel 34 7/2.50 7.50 94.00 155
Rabbit 55 7/3.15 9.45 149.20 210
Raccoon 80 7/3.81 11.43 218.26 290
Dog 100 7/4.26 12.78 272.86 325
Dog-up 125 19/2.89 14.45 342.51 360
Coyote 148 19/3.15 15.75 406.91 400
Wolf 173 19/3.40 17.0 474.02 460
Wolf-up 200 19/3.66 18.3 549.40 480
Panther 232 19/3.94 19.75 636.63 520
Panther-up1 288 37/3.15 22.05 794.05 610
Panther-up2 346 37/3.45 24.15 952.56 720
Kundah 400 37/3.71 25.97 1101.63 740
Zebra 465 37/4.00 28.0 1280.50 800
Zebra-up 525 61/3.31 29.79 1448.39 875
Moose 570 61/3.45 31.05 1573.71 900
Morkulla 604 61/3.55 31.95 1666.00 920
Moose-up 642 61/3.66 32.94 1771.36 940
Morkulla-up 695 61/3.81 34.29 1919.13 960
Bersimis 767 61/4.00 36.0 2115.54 1000
Type Ah GOST 839-80
Nominal Cross Section Calculated Cross Section Number of  ires Conductor Diameter DC Resistance at 20 Min. Breaking Load Conductor Weight
mm2 mm2 mm Ω N kg/km
16 15.9 7 5.1 1.9037 3734 43
25 24.9 7 6.4 1.2139 5370 68
35 34.3 7 7.5 0.8819 7389 94
50 49.5 7 9 0.6121 10662 135
120 117 19 14 0.2609 25186 321
150 148 19 15.8 0.2059 31900 406
185 182.3 19 17.5 0.1669 39386 502
Type Ankp GOST 839-80
Nominal Cross Section Calculated Corss Section Number of  Wires Conductor Diameter DC Resistance at 20 Min. Breaking Load Conductor Weight Grease Weight
mm2 mm2 mm Ω N kg/km kg/km
16 15.9 7 5.1 1.9037 3734 43 0.5
25 24.9 7 6.4 1.2139 5370 68 0.5
35 34.3 7 7.5 0.8819 7389 94 0.5
50 49.5 7 9 0.6121 10662 135
120 117 19 14 0.2609 25186 321
150 148 19 15.8 0.2059 31900 406
185 182.3 19 17.5 0.1669

Case Video

Certificate Display

Factory Tour

Why choose us?

Professional

20+ years cable export experience, with full knowledges of all kinds STANDARDS, we have EN/ES/FR sales for deep communications.

Professional

20+ years cable export experience, with full knowledges of all kinds STANDARDS, we have EN/ES/FR sales for deep communications.
Read More

Fast Delivery

Our factory has sufficient capacity, and we can generally complete production for most orders within 2 ~ 3 weeks, maximum 1 ~ 1.5 months.

Fast Delivery

Our factory has sufficient capacity, and we can generally complete production for most orders within 2 ~ 3 weeks, maximum 1 ~ 1.5 months.
Read More

Good Price

Relying on robust Chinese cable manufacturing supply chain enables us to maintain low costs, to offer competitive cable products to our customers.

Good Price

Relying on robust Chinese cable manufacturing supply chain enables us to maintain low costs, to offer competitive cable products to our customers.
Read More

High Quality

We have complete cable type tests and a quality inspection process, supporting customer or third-party quality acceptance to ensure we deliver high-quality products.

High Quality

We have complete cable type tests and a quality inspection process, supporting customer or third-party quality acceptance to ensure we deliver high-quality products.
Read More

FAQs

Who are we?

We are Manufacturer more than 21 years experience in Binzhou City, shangdong, China. We start from 2004, sell to Domestic Market(52.00%), Eastern Asia(25.00%), Africa(10.00%), Mid East(6.00%),Southeast Asia(4.00%),South Asia(3.00%). There are total about 301-500 people in our office.

Always a pre-production sample before mass production; Always have strict control of the quality from the raw material to finished products according to ISO9001 QC system before shipment.

House eletric wire, Anti-aging wire, Solar PV cable, Control cable, Shielded computer cable, Low/Medium/High Voltage power cable, Aluminum alloy cable, Aerial insulated cable, Steel core aluminum standed wire, LSZH cable, Fireproof cable, Wind power cable, EV charging cable, Energy storage cable, Mining cable, etc.

hengwang cable company has passed ISO9001 quality management system, ISO14001 environmental management system, ISO45001\German TUV certification\CE certification, the company is a finalist for the state power grid and a national”High-tech Enterprise.

Accepted Delivery Terms: FOB,CFR,EXW,FAS,DDP; Accepted Payment Currency:USD,EUR,CAD,AUD,GBP,CNY; Accepted Payment Type: T/T,L/C,MoneyGram,Credit Card,Western Union,Cash; Language Spoken:English,Chinese,Japanese,German,Russian

Yes, we have production line for packing box and cartons. we can make it according to your special requirement. If you are interested in our goods , please kindly send an inquiry to us !

Contact us to get your quote!