TAAAC TAL Thermal Resistant Aluminum Alloy Conductors

  • Bare ConductorTags: taaac conductor, Thermal Resistant All Aluminum Alloy Conductor

  • 2KM;

  • T/T, L/C, MoneyGram, Credit Card, Western Union, Cash;

  • Shipping fee and delivery date to be negotiated. Chat with supplier now for more details;

  • Every payment you make is secured with strict SSL encryption and PCI DSS data protection protocols;

  • FOB, CFR, EXW, FAS, DDP;

  • USD, EUR, CAD, AUD, GBP, CNY

Product Description

TAAAC TAL Thermal Resistant Aluminum Alloy Conductors

TAAAC Application

Thermal Resistant Aluminum-alloy Conductors(TAL). Used for overhead power lines, ground wires, steel stay wires

Urban network capacity transformation, substation, power plant construction and general lines

TAAAC Conductor Standards

IEC 61089; JEC 3406; IEC 62004;

Hight Temperature Characteristics

(Compared with conventional ACSR)
1.Long-term working temperature of 150℃, short-term temperature up to 180℃, so that the continuous allowable carrying capacity of the same specification of ordinary wire 1.5~1.6 times.
2.Under normal temperature, with ordinary aluminum wire has the same strength, high temperature operation mechanical strength retention rate can be maintained at more than 90%.
3.Compared with ordinary aluminum wire, it has the same creep properties at room temperature or high temperature.
4.There is no significant difference between the salt spray test in laboratory and the outdoor air exposure test.
5.Installation and maintenance are the same as ordinary wire installation procedures, without any special tools, tooling, installation and maintenance are convenient, and the cost is low.

Nominal cross-section areaConstructionCalculated cross-section areaApprox. Overall diameterApprox. Overall weightMaximum DC resistance at 20oCRated strength
mm2No.xmmmm2mmkg/kmΩ/kmkN
24019 x 4.0238.820.06550.122034.2
40037 x 3.7397.825.910970.073758.0
51037 x 4.2512.529.414130.057173.3
66061 x 3.7655.833.318120.044895.6
85061 x 4.2844.937.823340.0342120.9
98091 x 3.7978.340.727140.0302142.7
103091 x 3.8103241.828640.0286150.5
126091 x 4.2126046.234990.0234180.3
1600127 x 4.0159652.044400.0186228.5
2020127 x 4.5201958.556160.0147289.0
2500127 x 5.0249465.069370.0118357.0

 

Nominal cross-section areaConstructionCalculated cross-section areaApprox. Overall diameterApprox. Overall weightMaximum DC resistance at 20oCRated strength
mm2No.xmmmm2mmkg/kmΩ/kmkN
24019 x 4.0238.820.06550.126034.2
40037 x 3.7397.825.910970.076458.0
51037 x 4.2512.529.414130.059373.3
66061 x 3.7655.833.318120.046595.6
85061 x 4.2844.937.823340.0361120.9
98091 x 3.7978.340.727140.0313142.7
103091 x 3.8103241.828640.0296150.5
126091 x 4.2126046.234990.0243180.3
1600127 x 4.0159652.044400.0191228.5
2020127 x 4.5201958.556160.0152289.0
2500127 x 5.0249465.069370.0122357.0