Bare Copper Stranded Conductor ( BCC )

  • Bare ConductorTag: Stranded bare copper conductor

  • 2KM;

  • T/T, L/C, MoneyGram, Credit Card, Western Union, Cash;

  • Shipping fee and delivery date to be negotiated. Chat with supplier now for more details;

  • Every payment you make is secured with strict SSL encryption and PCI DSS data protection protocols;

  • FOB, CFR, EXW, FAS, DDP;

  • USD, EUR, CAD, AUD, GBP, CNY

Product Description

Bare Copper Stranded Conductor ( BCC )

Overhead transmission Bare Copper Conductor

Bare Stranded Hard-Drawn Copper Conductors Application

Stranded Class 2 bare copper wire to BS EN 60228 / IEC 60228 cables are non insulated and non sheathed soft drawn copper to BS6360/81. Stranded bare soft or annealed copper conductors are recommended for use as neutrals, in circuit ground connections as well as machinery and equipment grounding systems. Soft copper may be used for transformer drop leads or other non-tension hook-up jumpers.
Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications. Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook up, jumpers, and grounds in electrical construction. Soft Drawn copper is unilay construction.

Bare Stranded Hard-Drawn Copper Conductors Standards

· BS 6360 and BS EN 60228 / IEC 60228

· ASTM B-1 Hard-Drawn Copper Wire.

· ASTM B-2 Medium-Hard Copper Wire.

· ASTM B-3 Soft or Annealed Copper Wire.

· ASTM B-787 19 Wire Combination Unilay-Stranded Soft copper wire.

· ASTM B-8 Concentric-Lay-Stranded Hard, Medium-Hard or Soft Copper Conductor.

Bare Stranded Hard-Drawn Copper Conductors Construction

Bare copper, solid or stranded. Available in tempers hard, medium-hard, or soft. Stranded conductors are concentrically stranded in hard and medium-hard tempers and are Combination Unilay stranded in the soft-drawn temper.

Bare Stranded Hard-Drawn Copper Conductors Characteristics

Stranded bare soft or annealed copper conductors are suitable for direct burial and do not suffer from the inherent corrosion problems that an aluminum conductor would. Copper is almost twice as conductive as aluminum. Copper is easier than aluminum to terminate and join at splices and joints.

Size
AWG or MCM
or KCMIl
Actual cross-sectional area
mm2
Number
of single wire
Diameter of single wire
mm
Nominal Overall Diameter
mm
Approximate weight
kg/km
Current
Rating
A
105.370.983.274850
88.371.233.697695
613.471.564.68121130
421.171.965.88192170
326.672.26.6242200
233.572.477.41305230
142.572.788.34384265
1/053.573.129.35485310
1/054.4191.919.47485310
2/067.773.5110.52611355
2/067.7192.1310.62611355
3/085.373.9411.79771410
3/085.2192.3911.94771410
4/0107.474.4213.26972480
4/0108192.6913.41972480
250127.2192.9214.581149530
250125.7372.0814.611149530
300152.8193.215.951378590
300152.4372.29161378590
350177.6193.4517.251609650
350175.9372.4617.31609650
400203.2193.6918.421838
400202.5372.6418.491838
500252.9372.9520.682297810
600303.2373.2322.632757910
381750381612.8225.3534461040
5061000506613.2529.2645951240
6311250631.3613.6332.8457421451
6221250622912.9532.7457421430
7591500758.9613.9835.8468911669
7551500754.9913.2535.8668911669

 

Nominal cross-sectional area
mm2
No./Diameter of single wire
mm
Nominal overall diameter
mm
Approximate weight of cable
kg/km
Nominal Breaking Load
Kn
Maximum DC
Resistance at 20℃
Ω/km
107/1.354.05904.2921.8054
167/1.705.11256.8011.1385
257/2.146.4216010.5450.7185
357/2.527.5620014.2980.5181
507/3.029.0625020.5310.3589
5019/1.788.925019.8060.3825
7019/2.1410.731028.6260.2646
9519/2.5212.638038.8180.1918
12019/2.8514.2544049.6570.1492
15037/2.2515.7551061.6320.1238
18537/2.5217.6458575.5870.0981
24061/2.2520.25700101.6160.0752
30061/2.5222.68800124.6270.06
40061/2.8525.65960159.4070.0469
50061/3.2028.81110200.9590.037