返回顶部
图片处理需求 (1)
图片处理需求 (2)

N2XSY Cable

  • Category: Low & Medium Voltage Cable

Product Description

Product Description

N2XSY Cable | XLPE Insulated Single-Core Cable with PVC Outer Sheath (6/10 kV, 12/20 kV, 18/30 kV)

N2XSY Cable Application

To be laid directly in ground, outdoors, indoors and in cable ducts.

N2XSY Cable Construction

图片处理需求.jpg

1…..stranded (RM) bare copper
2…..inner layer of semi-conducting material
3…..core insulation of cross-linked polyethylene
4…..outer layer of semi-conducting material
5…..screen of copper wires
6…..outer sheath of polyvinylchloride (PVC), red

N2XSY Cable Standards

DIN VDE 0276-620 HD 620 S1: 1995 DIN EN 60228 class 2 (construction)


N2XSY Cable Technical data

Test voltage6 / 10 kV[kV]21 / 5 min.
 12 / 20 kV[kV]42 / 5 min.
 18 / 30 kV[kV]63 / 5 min.
Temperature rangein motion – 5°C till +70°C
 fixed -20°C till +70°C
Operating temperatureshort circuit°C250
Short circuit timemax.[sec]5
Bending radiusmin.x diameter15
Flammabilitystandard EN 60332-1-2

 

Number of cores and nominal cross section mm²Copper figure kg/kmOverall diameter appr. mmOverall diameter max. value appr. mmWeight appr. kg / kmCurrent carrying capacity ground A*Current carrying capacity air A*
6 / 10 kV      
1 x 35 RM/16518,402328900187197
1 x 50 RM/16662,4024291.050220236
1 x 70 RM/16854,4026311.300268294
1 x 95 RM/161.094,4027321.600320358
1 x 120 RM/161.334,4029341.850363413
1 x 150 RM/251.723,2030352.200405468
1 x 185 RM/252.059,2032372.600456535
1 x 240 RM/252.587,2034393.150526631
1 x 300 RM/253.163,2036403.750591722
1 x 400 RM/354.233,6040454.650662827
1 x 500 RM/355.193,6043475.750739921

 

Number of cores and nominal cross section mm²Copper figure kg/kmOverall diameter appr. mmOverall diameter max. value appr. mmWeight appr. kg / kmCurrent carrying capacity ground A*Current carrying capacity air A*
12 / 20 kV      
1 x 35 RM/16518,4027321.100189200
1 x 50 RM/16662,4028331.250222239
1 x 70 RM/16854,4030351.450271297
1 x 95 RM/161.094,4031361.750323361
1 x 120 RM/161.334,4033382.050367416
1 x 150 RM/251.723,2034392.400409470
1 x 185 RM/252.059,2036412.800461538
1 x 240 RM/252.587,2039443.400532634
1 x 300 RM/253.163,2041464.000599724
1 x 400 RM/354.233,6044494.950671829
1 x 500 RM/355.193,6047526.050754953

 

Number of cores and nominal cross section mm²Copper figure kg/kmOverall diameter appr. mmOverall diameter max. value appr. mmWeight appr. kg / kmCurrent carrying capacity ground A*Current carrying capacity air A*
18 / 30 kV      
1 x 50 RM/16662,4033381.450225241
1 x 70 RM/16854,4035401.700274299
1 x 95 RM/161.094,4036412.050327363
1 x 120 RM/161.334,4038432.300371418
1 x 150 RM/251.723,2039442.700414472
1 x 185 RM/252.059,2041463.100466539
1 x 240 RM/252.587,2043483.700539635
1 x 300 RM/253.163,2046514.350606725
1 x 400 RM/354.233,6049545.300680831
1 x 500 RM/355.193,6052576.450765953