返回顶部
图片处理需求 (1)
图片处理需求 (2)
图片处理需求 (3)
图片处理需求
图片处理需求 (2)(1)

Single Phase Concentric Aluminium Cable-Kenya

  • Concentric Service Cable

  • Aluminum Concentric Service Cable

  • 2KM

  • T/T, L/C, MoneyGram, Credit Card, Western Union, Cash;

  • Shipping fee and delivery date to be negotiated. Chat with supplier now for more details;

  • Every payment you make is secured with strict SSL encryption and PCI DSS data protection protocols;

  • FOB, CFR, EXW, FAS, DDP;

  • USD, EUR, CAD, AUD, GBP, CNY

Product Description


Product Description

Single Phase Concentric Aluminium Cable-Kenya

PVC Insulated Single phase concentric aluminum cable service entrance cable, rating voltage 600/1000V

PVC Insulated Single phase concentric aluminium cable with/without copper communication pair -Kenya Standard: KS

Aluminum Concentric Service Cable Application

Service entrance cable, rating voltage 600/1000V.

Type I: PVC Insulated Single phase concentric aluminum cable with copper communication pair

1,Conductor: Aluminum Wire,

2,Insulation: Red PVC

3,,Neutral Conductor: PE Insulated Aluminum Wire

4,Communication Pair:2 White Blue

5,Binder Tape: Polyester Tape

6,Outer Sheath:Black PVC

Type II: PVC Insulated Single phase concentric aluminum cable without copper communication pair-KS 04-1022


1789637945471622.png

1,Conductor: Aluminum Wire,

2,Insulation: Red PVC

3,,Neutral Conductor: Bare Aluminum Wire

4,Binder Tape: Polyester Tape

5,Outer Sheath:Black PVC


0.6/1kV Aerial Bundle Cable ASNZS 3560.1 Specifications

PropertyCable sizes
Phase ConductorNominal area, mm,10162535
Form of conductorsCircular/compacted circular stranded
No. & approx, dia. of wires, No./mm7/1.357/1.707/2.147/2.52
Min-Max. dia of completed conductors, mm*4.6-5.25.6-6.56.6-7.6
 Nominal diameter of conductors, mm4.055.106.427.56
 Minimum thickness of insulation mm1.551.551.601.65
Concentric neutral Approx, no. of wires7111416
Concentric neutral Approx, diameter of wires, mm1.501.501.501.50
Minimum lay lengths, mm146.5155165178
Thickness of over sheath, mm1.41.41.51.6
Minimum thickness of over sheath at any point1.091.091.171.20
Maximum conductor DC resistance per 1000m of cable
at 20°C
Phase, Ω3.081.151.200.868
Neutral-earth, Ω4.613.081.911.20
Maximum weight of the complete conductor excluding insulation*43.969.596.4
Power frequency withstand voltage, for 5mins, kVrms3.5
Insulation resistance at 500Vdc in 1min at 20qC., MQ/Km8865
* Manufacturer to state the design value based on the sizes of conductors specified

 

Phase ConductorConcentric neutral conductor: number. & approx, diameter of wires
No,/mm
Minimum lay lengthsThickness of over sheath mmApproxmate overall diameterMaximum conductor DC resistance per 1000m of cable at 20°C
Nominal areaNo.
&approx.dia. of wires mm
Thickness of insulation mmPhase ohmsNeutral ohms
107/1.351.5523/1.13146.51.412.213.081.335
167/1.701.5526/1.131551.413.341.911.808
257/2.141.6029/1.131651.514.881.201.0586
3519/1.531.6527/1.351781.616.750.8680.7966