SAC Spaced Aerial Cable
SAC Spaced Aerial Cable ICEA S-66-524
Spaced Aerial Cable Application
This kind of spaced aerial cable ( SAC cable) is used for aerial power transmission at 15/25/35 maximum system voltage. the phase to phase voltage is 10/20/33KV. This standard applies of supported spacer cable. These conductors are intended primarily for the distribution of electrical energy under normal conditions of overhead (aerial) installations. They are considered as covered conductors therefore the cables carry no voltage rating. The conductors must be installed on insulators and/or spacers adequate for the service voltage. The user may want to give consideration to the dielectric compatibility of the covering, insulator, spacer.
Spaced Aerial Cable Construction
Conductors: Stranded compacted circular hard drawn aluminium wire.
Conductor screen: Extruded semi-conductive compound
Insulation: Cross-linked polyethylene (XLPE). Color : Natural
Sheath: Track resistant Cross-linked polyethylene (XLPE) / HDPE. Color : Black
SAC Spaced Aerial Cable Characteristics
· Voltage Rating: 15kV. 25KV. 35KV
· Operating Temperature: -40°C to +90°C .
· Minimum Laying/ Installation Temperature: -20°C .
· Max operating temperature of conductor. When cable short-circuited(5s maximum duration): 250℃
· Test Voltage: AC. 27kV 5min No Breakdown(For 15KV SAC Cable).
AC. 38kV 5min No Breakdown(For 25KV SAC Cable).
AC. 49kV 5min No Breakdown(For 35KV SAC Cable).
· Minimum Bending Radius: 15 x OD (Overall Diameter)
| Nominal Size | Min.No. of Wires | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
|---|---|---|---|---|---|---|---|
| Conductor Shield | Inner Layer | Outer Layer | |||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 15kV AAC/XLPE/XLPE | |||||||
| 25 | 6 | 0.60 | 1.91 | 1.91 | 15.2 | 3762 | 218 |
| 35 | 6 | 0.60 | 1.91 | 1.91 | 16.2 | 5177 | 258 |
| 50 | 6 | 0.60 | 1.91 | 1.91 | 17.3 | 7011 | 307 |
| 70 | 12 | 0.60 | 1.91 | 1.91 | 19.0 | 10354 | 387 |
| 95 | 15 | 0.60 | 1.91 | 1.91 | 20.8 | 13727 | 482 |
| 120 | 15 | 0.60 | 1.91 | 1.91 | 22.0 | 17339 | 564 |
| 150 | 15 | 0.60 | 1.91 | 1.91 | 23.7 | 21033 | 660 |
| 185 | 30 | 0.60 | 1.91 | 1.91 | 25.3 | 26732 | 780 |
| 240 | 30 | 0.60 | 1.91 | 1.91 | 27.6 | 34679 | 968 |
| Nominal Size | Min. No. of Wires | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
|---|---|---|---|---|---|---|---|
| Conductor Shield | Inner Layer | Outer Layer | |||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 25kV AAC/XLPE/XLPE | |||||||
| 25 | 6 | 0.70 | 3.18 | 3.18 | 20.1 | 3762 | 351 |
| 35 | 6 | 0.70 | 3.18 | 3.18 | 21.1 | 5177 | 398 |
| 50 | 6 | 0.70 | 3.18 | 3.18 | 22.2 | 7011 | 455 |
| 70 | 12 | 0.70 | 3.18 | 3.18 | 23.9 | 10354 | 548 |
| 95 | 15 | 0.70 | 3.18 | 3.18 | 25.7 | 13727 | 657 |
| 120 | 15 | 0.70 | 3.18 | 3.18 | 26.9 | 17339 | 748 |
| 150 | 15 | 0.70 | 3.18 | 3.18 | 28.6 | 21033 | 856 |
| 185 | 30 | 0.70 | 3.18 | 3.18 | 30.2 | 26732 | 989 |
| 240 | 30 | 0.70 | 3.18 | 3.18 | 32.5 | 34679 | 1195 |
| Nominal Size | Min. No. of Wires | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
|---|---|---|---|---|---|---|---|
| Conductor Shield | Inner Layer | Outer Layer | |||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 35kV AAC/XLPE/XLPE | |||||||
| 25 | 6 | 0.70 | 4.45 | 3.18 | 22.6 | 3762 | 433 |
| 35 | 6 | 0.70 | 4.45 | 3.18 | 23.6 | 5177 | 485 |
| 50 | 6 | 0.70 | 4.45 | 3.18 | 24.7 | 7011 | 545 |
| 70 | 12 | 0.70 | 4.45 | 3.18 | 26.4 | 10354 | 645 |
| 95 | 15 | 0.70 | 4.45 | 3.18 | 28.2 | 13727 | 761 |
| 120 | 15 | 0.70 | 4.45 | 3.18 | 29.4 | 17339 | 856 |
| 150 | 15 | 0.70 | 4.45 | 3.18 | 31.1 | 21033 | 971 |
| 185 | 30 | 0.70 | 4.45 | 3.18 | 32.7 | 26732 | 1110 |
| 240 | 30 | 0.70 | 4.45 | 3.18 | 35.0 | 34679 | 1324 |
| Nominal Size | Min. No. of Wires | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
|---|---|---|---|---|---|---|---|
| Conductor Shield | Inner Layer | Outer Layer | |||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 15kV AAC/XLPE/HDPE | |||||||
| 25 | 6 | 0.60 | 1.91 | 1.91 | 15.2 | 3762 | 221 |
| 35 | 6 | 0.60 | 1.91 | 1.91 | 16.2 | 5177 | 261 |
| 50 | 6 | 0.60 | 1.91 | 1.91 | 17.3 | 7011 | 310 |
| 70 | 12 | 0.60 | 1.91 | 1.91 | 19.0 | 10354 | 390 |
| 95 | 15 | 0.60 | 1.91 | 1.91 | 20.8 | 13727 | 486 |
| 120 | 15 | 0.60 | 1.91 | 1.91 | 22.0 | 17339 | 568 |
| 150 | 15 | 0.60 | 1.91 | 1.91 | 23.7 | 21033 | 664 |
| 185 | 30 | 0.60 | 1.91 | 1.91 | 25.3 | 26732 | 785 |
| 240 | 30 | 0.60 | 1.91 | 1.91 | 27.6 | 34679 | 973 |
| Nominal Size | Min. No. of Wires | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
|---|---|---|---|---|---|---|---|
| Conductor Shield | Inner Layer | Outer Layer | |||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 25kV AAC/XLPE/HDPE | |||||||
| 25 | 6 | 0.70 | 3.18 | 3.18 | 20.1 | 3762 | 356 |
| 35 | 6 | 0.70 | 3.18 | 3.18 | 21.1 | 5177 | 404 |
| 50 | 6 | 0.70 | 3.18 | 3.18 | 22.2 | 7011 | 461 |
| 70 | 12 | 0.70 | 3.18 | 3.18 | 23.9 | 10354 | 555 |
| 95 | 15 | 0.70 | 3.18 | 3.18 | 25.7 | 13727 | 664 |
| 120 | 15 | 0.70 | 3.18 | 3.18 | 26.9 | 17339 | 755 |
| 150 | 15 | 0.70 | 3.18 | 3.18 | 28.6 | 21033 | 864 |
| 185 | 30 | 0.70 | 3.18 | 3.18 | 30.2 | 26732 | 997 |
| 240 | 30 | 0.70 | 3.18 | 3.18 | 32.5 | 34679 | 1203 |
| Nominal Size | Min. No. of Wires | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
|---|---|---|---|---|---|---|---|
| Conductor Shield | Inner Layer | Outer Layer | |||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 35kV AAC/XLPE/HDPE | |||||||
| 25 | 6 | 0.70 | 4.45 | 3.18 | 22.6 | 3762 | 439 |
| 35 | 6 | 0.70 | 4.45 | 3.18 | 23.6 | 5177 | 491 |
| 50 | 6 | 0.70 | 4.45 | 3.18 | 24.7 | 7011 | 552 |
| 70 | 12 | 0.70 | 4.45 | 3.18 | 26.4 | 10354 | 652 |
| 95 | 15 | 0.70 | 4.45 | 3.18 | 28.2 | 13727 | 768 |
| 120 | 15 | 0.70 | 4.45 | 3.18 | 29.4 | 17339 | 864 |
| 150 | 15 | 0.70 | 4.45 | 3.18 | 31.1 | 21033 | 980 |
| 185 | 30 | 0.70 | 4.45 | 3.18 | 32.7 | 26732 | 1119 |
| 240 | 30 | 0.70 | 4.45 | 3.18 | 35.0 | 34679 | 1334 |