返回顶部
生成高清无水印图片
生成高清无水印图片 (1)
生成高清无水印图片 (3)
生成高清无水印图片 (4)
生成高清无水印图片 (5)

IEC 60502-2 MV ABC Cable

  • ABC Cable / Aerial Bundled CableTags: 1kv Medium Voltage ABC Cable, 33kv Aerial Bundled Cable, MV ABC Cable

  • 2KM;

  • T/T, L/C, MoneyGram, Credit Card, Western Union, Cash;

  • Shipping fee and delivery date to be negotiated. Chat with supplier now for more details;

  • Every payment you make is secured with strict SSL encryption and PCI DSS data protection protocols;

  • FOB, CFR, EXW, FAS, DDP;

  • USD, EUR, CAD, AUD, GBP, CNY.

Product Description

MV ABC Cable Application

11KV 33KV MV ABC Cable Aerial Bundled Cable is a new type of aerial cable for power transmitting. It is extensively used in overhead power transmission line. Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. It improves the safety and reliance of electrified wire netting. The products primarily used for the distribution of electrical energy under normal conditions of overhead (aerial) installations.The conductors must be installed on insulators and/or spacers adequate for the service voltage. The user may want to give consideration to the dielectric compatibility of the covering, insulator, spacer etc.

Aerial Insulated Cable Description

The conductors are stranded,circular compressed aluminum, aluminum-alloy, copper. The conductor screen is the extruded Semi-conducting conductor shield in Black. And the outer Insulation is mainly thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE) in Black with Weather or UV resistant. This standard covers both thermoplastic and cross linked polyethylene constructions, rated for 75°C or 90°C normal service temperature.



MV Overhead insulated Cable Specifications

Phase ConductorCircular Compacted Stranded H68 Aluminium ( Class 2)
Conductor ScreenExtruded Semi-conductive Layer.
InsulationXLPE.
Insulation ScreenExtruded Semi-conductive Layer.
Metallic ScreenCopper wire screen or copper tape screen
SeparatorSemi-conductive swellable tape.
Outer SheathHDPE.
Support ConductorGalvanized steel wires.
AssemblyXLPE insulated screened cores are bundled around the galvanized steel wires in a right hand lay

 

Number of Cores
xNominal
Cross Section
Phase ConductorMessenger Suspension UnitContinuous
current
rating
at
300C
ambient
temp
StrandingNominal Sectional AreaMaximum
Conductor
Resistance
StrandingNominal Sectional AreaBreaking
Load
No.×mm^2No.×mmmm^2Ω/KmNo.×mmmm^2KNA
3X50 + 1X2519/1.78500.6417/3.05060116
3X70 + 1X5019/.14700.4437/3.155062210
3X95+ 1X5019/2.52950.327/3.05060173
3X185+1X12037/2.521850.1647/4.67120150259
3X150 +1X5037/2.251500.2067/3.155062365
3X240 +1X5061/2.252400.1257/3.155062500

 

Number of Cores
xNominal
Cross Section
Phase ConductorMessenger Suspension UnitContinuous
current
rating
at
300C
ambient
temp
StrandingNominal Sectional AreaMaximum
Conductor
Resistance
StrandingNominal Sectional AreaBreaking
Load
No.×mm^2No.×mmmm^2Ω/KmNo.×mmmm^2KNA
3X50 + 1X5019/1.78500.6417/3.05060165
3X150+ 1X5037/2.251500.2067/3.05060315
3X185+1X7037/2.521850.1647/3.577091355
3X70 +1X5019/2.1470.4437/3.155062250
3X150 +1X5037/2.251500.2067/3.155062370

 

TypeNo. of CoresNominal size mm2
CU/XLPE,AAC/XLPE,AAAC/XLPE110 ~ 400
325 ~ 400
3+k(A) or 3+k(B)25 ~ 400 ; k:25~120
CU/PE,AAC/PE,AAAC/PE,CU/XLPE,AAC/XLPE,AAAC/XLPE110 ~ 400
AAC/XLPE,AAAC/XLPE325 ~ 400
3+k(A) or 3+k(B)25 ~ 400 ; k:25~120
The k is a load-bearing core. (A) means steel carrying stranded wire, (B) means aluminum alloy carrying stranded wire.

 

Nominal SizeMin. No.
of Wires
Approx. Diameter of ConductorMin.
Thickness of Conductor screen
 
(Approx.)
Nominal Thickness of InsulationNominal Thickness of Insulation ScreenMax. DC Resistance at 20 0CMin. Breaking Load
ReducedNominalHard CopperSoft CopperHard Copper
mm2No.mmmmmmmmmmΩ/kmΩ/kmN
1063.80.53.41.830
1664.80.53.41.150
2566.00.52.53.41.00.7490.7278465
3567.00.52.53.41.00.5400.52411731
5068.30.52.53.41.00.3990.38716052
701210.00.52.53.41.00.2760.26823461
951511.60.62.53.41.00.1990.19331759
1201813.00.62.53.41.00.1580.15339911
1501814.60.62.53.41.00.12849505
1853016.20.62.53.41.00.102161846
2403418.40.62.53.41.00.077779823
3003420.60.62.53.41.00.061999788
4005323.80.62.53.41.00.0484133040

 

Nominal SizeMin. No.
of Wires
Approx. Diameter of ConductorMin.
Thickness of Conductor Screen
 
(Approx.)
Nominal Thickness of InsulationNominal Thickness of Insulation ScreenMax. DC Resistance at
20 0C
Min. Breaking Load
ReducedNominalAACAAACAACAAAC
mm2No.mmmmmmmmmmΩ/kmΩ/kmNN
1063.80.53.43.0803.574
1664.80.53.41.9102.217
2566.00.52.53.41.01.2001.39337626284
3567.00.52.53.41.00.8681.00751778800
5068.30.52.53.41.00.6410.744701112569
701210.00.52.53.41.00.4430.5141035417596
951511.60.62.53.41.00.3200.3711372723880
1201813.00.62.53.41.00.2530.2941733930164
1501814.60.62.53.41.00.2060.2392103337706
1853016.20.62.53.41.00.1640.1902673246503
2403418.40.62.53.41.00.1250.1453467960329
3003420.60.62.53.41.00.1000.1164334975411
4005323.80.62.53.41.00.07780.090455707100548

 

Size
(mm2)
No. and Dia.
of Wires
Conductor DiameterInsulation ThicknessCable DiameterRated
Strength
Weight
ALSt
No.No. /mmmmmmmmkgfkg/km
22.9 kV ACSR/AW-OC/XLPE
326/**1/2.67.23.013.21090210
586/**1/3.59.73.015.71900330
956/**1/3.512.03.519.02360530
16018/**1/3.215.44.023.43080730
24018/**1/4.018.94.027.045001040